{"id":3175,"date":"2021-11-04T15:13:06","date_gmt":"2021-11-04T07:13:06","guid":{"rendered":"https:\/\/epcpmo.com\/?p=3175"},"modified":"2022-09-11T15:25:52","modified_gmt":"2022-09-11T07:25:52","slug":"five-star-hotel-decoration-and-sound-insulation-construction-2","status":"publish","type":"post","link":"https:\/\/epcpmo.com\/en\/five-star-hotel-decoration-and-sound-insulation-construction-2\/","title":{"rendered":"Five-star hotel decoration and sound insulation construction (2)"},"content":{"rendered":"<h4 class=\"wp-block-heading\"><a id=\"post-3175-activity-name\"><\/a><a id=\"post-3175-img-content\"><\/a><a id=\"post-3175-page-content\"><\/a><a id=\"post-3175-js_article\"><\/a>Hotel decorated with soundproofing<\/h4>\n\n\n\n<p><a id=\"post-3175-js_content\"><\/a>\n<\/p>\n\n\n\n<p><strong>1. <\/strong>Most decorative soundproofing is done only in sound-absorbing fillers and walls Thickening surface kung fu, this hotel acoustic data contains 3 common wall types of 7 special sound insulation solutions to solve the problem of sound insulation essence. \n<\/p>\n\n\n\n<p><strong>2. From <\/strong>the building sound insulation requirements, 5 acoustic measures such as active wall noise reduction, door and window noise reduction, ground noise reduction processing, equipment noise reduction, etc. are provided.  \n<\/p>\n\n\n\n<p><strong>01<\/strong>\n<\/p>\n\n\n\n<p><strong>Hotel acoustic design standards<\/strong>\n<\/p>\n\n\n\n<p><strong>1. In conjunction with the building acoustic standards, develop the soundproofing standards applicable to the hotel:<\/strong>\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1080\" height=\"1154\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153.jpeg\" alt=\"\" class=\"wp-image-3177\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153-281x300.jpeg 281w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153-958x1024.jpeg 958w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153-768x821.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-153-600x641.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Noun interpretation: Sound level(STC,in<\/strong> <strong>dB).<\/strong>\n<\/p>\n\n\n\n<p>   0 decibels(dB), barely audible sounds, such as the sound of a breeze moving leaves <\/p>\n\n\n\n<p>   20 decibels(dB), low murmurs, quiet office sounds <\/p>\n\n\n\n<p>   40 decibels(dB), pendulum sound, general office talk <\/p>\n\n\n\n<p>   80 decibels(dB), the sound of the street <\/p>\n\n\n\n<p>   120 decibels(dB), the sound of the plane&#8217;s engine, will make the ear aching sound <\/p>\n\n\n\n<p>\n  The above refers to all acoustic data units in the applicable text\n  <br>\n<\/p>\n\n\n\n<p><strong>02<\/strong>\n<\/p>\n\n\n\n<p><strong>Acoustically compliant hotel interior partition scheme<\/strong>\n<\/p>\n\n\n\n<p>   According to the acoustic standards of the hotel above, there are currently 3 kinds of wall construction commonly used: masonry wall, masonry and gypsum board in line with the wall, gypsum board wall, we list the following different sound insulation wall structures, for the owner to choose reference: <\/p>\n\n\n\n<p><strong>1. STC60<\/strong> <strong>Wall Practice (Block Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>(STC<\/strong> <strong>is a laboratory sound level, such as<\/strong> <strong>STC60, STC50,<\/strong> and so <strong>on).<\/strong>  <\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>40mm thick cement mortar, 200mm thick concrete blocks, 40mm thick cement mortar, 50mm thick keel (inlaid with rock wool), 2x12mm thick gypsum board, 50mm Thick keel (inner-filled rock wool), and 12mm thick perforated sound-absorbent plate . . . 416mm <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img decoding=\"async\" width=\"1080\" height=\"1078\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154.jpeg\" alt=\"\" class=\"wp-image-3178\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-300x300.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-1024x1022.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-150x150.jpeg 150w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-768x767.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-600x599.jpeg 600w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-154-100x100.jpeg 100w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) the density of concrete blocks is not less than 600kg, the density of gypsum board is not less than 12kg, and the density of cement mortar is not less than 2000kg <\/p>\n\n\n\n<p>\n  (2) Gypsum board needs to be mis-stitched installation, all boards and plates, the ground and the ceiling between the contact should be sealed with soft sealant edge;\n<\/p>\n\n\n\n<p>\n  (3) Wall practice should be through the top, can not only achieve the height of smallpox;\n<\/p>\n\n\n\n<p>\n  (4)Pipeline through the wall location rock cotton filling, and cement mortar sealed; \n<\/p>\n\n\n\n<p>\n  (5)Perforated sound absorber penetration rate is greater than 18%.   \n<\/p>\n\n\n\n<p><strong>2. STC60<\/strong> <strong>Wall Practice (Lightweight Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>2x12mm thick gypsum board, 75mm light steel keel (inner-filled keel), 2x12mm thick gypsum board, 75mm light steel keel (air layer), 2x12mm thick gypsum board, 75mm  Light steel keel (inner-filled rock wool)  s 2x12mm thick gypsum board s 321mm <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img decoding=\"async\" width=\"1080\" height=\"1405\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155.jpeg\" alt=\"\" class=\"wp-image-3179\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155-231x300.jpeg 231w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155-787x1024.jpeg 787w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155-768x999.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-155-600x781.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) The contents of the rock wool weight are not less than 80kg, and the density of the gypsum board surface is not less than 12kg;\u00a0 <\/p>\n\n\n\n<p>   (2) Gypsum board needs to be installed by mistake, all boards and plates, the ground, and the ceiling between the contact should be sealed with soft sealant edge; <\/p>\n\n\n\n<p>   (3) Wall panel wire box side and back need to be sealed with gypsum board ceiling, avoid the terminal box back-to-back installation, junction box between at least 600mm.  <\/p>\n\n\n\n<p><strong>3.STC55 Wall Practice (Block Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>25mm thick cement mortar smudged with ash and 200mm thick concrete blocks with 25mm thick cement mortar smudged with 250mm\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1436\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156.jpeg\" alt=\"\" class=\"wp-image-3180\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156-226x300.jpeg 226w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156-770x1024.jpeg 770w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156-768x1021.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-156-600x798.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>\n  (1)block density is not less than 600kg;\n<\/p>\n\n\n\n<p>\n  (2) Wall practice should be through the top, can not only achieve the height of smallpox;\n<\/p>\n\n\n\n<p>\n  (3)Pipeline through the wall location rock cotton filling, and cement mortar blocking;\n<\/p>\n\n\n\n<p>\n  (4) Cement mortar density is not less than 2000kg.   \n<\/p>\n\n\n\n<p><strong>4. STC55 Wall Practice (Masonry and Gypsum Board Composite Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>2 x 12mm thick gypsum board, 50mm thick keel (inner-filled rock wool), 90mm thick aerated concrete block, 50mm thick keel (inner-filled kernel), 2 x 12mm thick gypsum board  238mm <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1440\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-157.jpeg\" alt=\"\" class=\"wp-image-3181\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-157.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-157-225x300.jpeg 225w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-157-768x1024.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-157-600x800.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) the contents of the rock wool capacity are not less than 80kg, the density of gypsum board is not less than 12kg, and the density of concrete blocks is not less than 600kg <\/p>\n\n\n\n<p>\n  (2) Gypsum board needs to be mis-stitched installation, all boards and plates, the ground and the ceiling between the contact should be sealed with soft sealant edge;\n<\/p>\n\n\n\n<p>   (3) Wall panel box side and back need to be sealed with gypsum board ceiling, avoid the terminal box back-to-back installation, at least 600mmbetween the terminal boxes.  <\/p>\n\n\n\n<p><strong>5.STC55 Wall Practice (Lightweight<\/strong> <strong>Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>2 x 12mm thick gypsum board, 50mm light steel keel (inner rock wool), 2 x 12mm thick gypsum board, 50mm light steel keel (inner rock cotton). 2 x 12mm thick gypsum board s 172mm <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1783\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158.jpeg\" alt=\"\" class=\"wp-image-3182\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158-182x300.jpeg 182w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158-620x1024.jpeg 620w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158-768x1268.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158-930x1536.jpeg 930w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-158-600x991.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) the contents of the rock wool weight are not less than 80kg, the density of gypsum board is not less than 12kg; <\/p>\n\n\n\n<p>\n  (2) Gypsum board needs to be mis-stitched installation, all boards and plates, the ground and the ceiling between the contact should be sealed with soft sealant edge;\n<\/p>\n\n\n\n<p>   (3) Wall panel box side and back need to be sealed with gypsum board ceiling, avoid the terminal box back-to-back installation, at least 600mmbetween the terminal boxes.  <\/p>\n\n\n\n<p><strong>6.STC50 Wall Practice (Block Wall):<\/strong> \n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>20mm thick cement mortar plaster smoldering morning smores  <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1723\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159.jpeg\" alt=\"\" class=\"wp-image-3183\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159-188x300.jpeg 188w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159-642x1024.jpeg 642w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159-768x1225.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159-963x1536.jpeg 963w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-159-600x957.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) block density is not less than 600kg, cement mortar density is not less than 2000kg <\/p>\n\n\n\n<p>\n  (2) Wall practice should be through the top, can not only achieve the height of smallpox;\n<\/p>\n\n\n\n<p>\n  (3)The pipe is filled with rock wool through the wall and sealed with cement mortar. \n<\/p>\n\n\n\n<p><strong>7.STC50 Wall Practice (Lightweight Wall):<\/strong>\n<\/p>\n\n\n\n<p><strong>Finished surface:<\/strong>2 x 12mm thick gypsum board, 100mm light steel keel (inlaid with rock wool), 2 x 12mm thick gypsum board, 148mm  <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"1686\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160.jpeg\" alt=\"\" class=\"wp-image-3184\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160-192x300.jpeg 192w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160-656x1024.jpeg 656w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160-768x1199.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160-984x1536.jpeg 984w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-160-600x937.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Note:<\/strong>\n  <br>\n<\/p>\n\n\n\n<p>   (1) the contents of the rock wool weight are not less than 80kg, the density of gypsum board is not less than 12kg;\u00a0 <\/p>\n\n\n\n<p>\n  (2) Gypsum board needs to be mis-stitched installation, all boards and plates, the ground and the ceiling between the contact should be sealed with soft sealant edge;\n<\/p>\n\n\n\n<p>   (3) Wall panel box side and back need to be sealed with gypsum board ceiling, avoid back-to-back installation of the terminal box, at least 600mmbetween the terminal boxes.  <\/p>\n\n\n\n<p><strong>03<\/strong>\n<\/p>\n\n\n\n<p><strong>Active partition walls,<\/strong> <strong>doors and windows,<\/strong> <strong>floors,<\/strong>  <strong>and<\/strong> <strong>device soundproofing control<\/strong>\n<\/p>\n\n\n\n<p><strong>1. Active partition soundproofing requirements:<\/strong>\n<\/p>\n\n\n\n<p>   For the active soundproof wall product, it must have an active pressure seal at the top, bottom, and sides, as follows are the acoustic requirements of the active partition wall: <\/p>\n\n\n\n<p>\n  (1) Conference room and banquet hall event soundproof wall The distance from the upper side of the elevator rail to the structural ceiling must be soundproofed. \n<\/p>\n\n\n\n<p><strong>Treatment:<\/strong>2 x 12mm gypsum board and light steel keel (filled with rock wool)s2 x 12mm gypsum board. The keel size depends on the width of the steel frame track, and the position through which the duct passes must be sealed to prevent sound from passing through the top of the soundproof wall.  (See the big picture below for details). \n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1076\" height=\"1074\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161.jpeg\" alt=\"\" class=\"wp-image-3185\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161.jpeg 1076w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-300x300.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-1024x1022.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-150x150.jpeg 150w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-768x767.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-600x599.jpeg 600w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-161-100x100.jpeg 100w\" sizes=\"(max-width: 1076px) 100vw, 1076px\" \/><\/figure>\n\n\n\n<p>\n  2) The amount of sound insulation on the active soundproof wall needs to be on STC53(decibels). \n<\/p>\n\n\n\n<p>   3) Banquet hall and conference room ceiling should be double-layered gypsum board, filled with the sound-absorbing cotton ceiling.  <\/p>\n\n\n\n<p>\n  4) For the wall of the pipe above the ceiling of the meeting room and banquet hall through the activity partition wall, we recommend sealing the pipe with rock wool and sealant with the gap around the wall. \n<\/p>\n\n\n\n<p><strong>As shown in the figure:<\/strong>\n  <br>\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"899\" height=\"1025\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-162.jpeg\" alt=\"\" class=\"wp-image-3186\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-162.jpeg 899w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-162-263x300.jpeg 263w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-162-768x876.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-162-600x684.jpeg 600w\" sizes=\"(max-width: 899px) 100vw, 899px\" \/><\/figure>\n\n\n\n<p><strong>2. Door soundproofing requirements:<\/strong>\n<\/p>\n\n\n\n<p>   Currently used in conference rooms, banquet halls, and guest rooms, the door, basically are wooden double doors, sound insulation is often the weakest link.   <br> <\/p>\n\n\n\n<p>   Because the surface density of the door is small, belongs to the thin enclosure components, the general sound insulation is between STC30-35  (decibel) so that the door gap processing must be in place because the gap around the door is an important way to transmit sound, which is the main reason for the door sound gap.  <\/p>\n\n\n\n<p>\n  The wall of the door occupies a smaller area than the wall, its low-frequency resonance also often occurs in the sensitive area of sound frequency, so the key to improve the sound insulation of the door is the material of the door itself and the seal of the surrounding gap, the following table shows the door gap affects the corresponding relationship of the sound insulation of the door itself:\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"453\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163.jpeg\" alt=\"\" class=\"wp-image-3187\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163-300x126.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163-1024x430.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163-768x322.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-163-600x252.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>The table above reflects that air gaps have a great impact on the sound insulation effect of the door, so we make the following three<\/strong> <strong>recommendations:<\/strong>\n<\/p>\n\n\n\n<p>\n  1) The door itself the amount of sound insulation should be above STC35(decibels).  \n<\/p>\n\n\n\n<p>   2) <strong>The door needs to be designed with a ladder to seal the door gap, the door frame ladder entrance needs to be installed with soundproofing to seal the gap. <\/strong> <\/p>\n\n\n\n<p>   3) If there is no door frame ladder, the door seal needs to be filled with compressible material, the filling material can be rubber or felt, coupled with a sealing pressure strip, so that the door sound insulation achieves its sound insulation standard.  <\/p>\n\n\n\n<p><strong>3. Curtain wall soundproofing requirements:<\/strong>\n<\/p>\n\n\n\n<p>   The curtain wall because it is connected to the outdoor, is the weak link of sound insulation. We give two hollow clamp curtain wall practices for the owner&#8217;s reference: <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"176\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388.png\" alt=\"\" class=\"wp-image-3188\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388.png 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388-300x49.png 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388-1024x167.png 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388-768x125.png 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-388-600x98.png 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Curtain wall and floor vertical gap blocking as far as possible to fill the way of rock wool, for the curtain wall and room wall horizontal junction part, is easy to leak the<\/strong> <strong>link, need to do a strict job of sealing, see the following practice diagram:<\/strong>\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"989\" height=\"1044\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164.jpeg\" alt=\"\" class=\"wp-image-3189\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164.jpeg 989w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164-284x300.jpeg 284w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164-970x1024.jpeg 970w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164-768x811.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-164-600x633.jpeg 600w\" sizes=\"(max-width: 989px) 100vw, 989px\" \/><\/figure>\n\n\n\n<p><strong>4. Ground sound insulation requirements:<\/strong>\n<\/p>\n\n\n\n<p>   Floor impact sound mainly comes from the upper area of the meeting room, we recommend the upper area of the ground carpet, carpet can achieve good impact elimination. <\/p>\n\n\n\n<p>\n  If there is no carpet, the need to do the vibration base under the corresponding ground decoration, the most commonly used ground decoration is stone floor tiles and wooden floors.\n<\/p>\n\n\n\n<p><strong>The structure of the upholstery recommended for installation under the wooden floor is as follows:<\/strong>\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"475\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165.jpeg\" alt=\"\" class=\"wp-image-3190\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165-300x132.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165-1024x450.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165-768x338.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-165-600x264.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>The structure of the upholstery recommended for installation under the floor tiles is as follows:<\/strong>\n  <br>\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"629\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166.jpeg\" alt=\"\" class=\"wp-image-3191\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166-300x175.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166-1024x596.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166-768x447.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-166-600x349.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>5. Toilet flushing noise requirements:<\/strong>\n<\/p>\n\n\n\n<p><strong>At present, the water pipe material is divided into cast iron, mute and PVC<\/strong> <strong>pipe, the specific noise reduction method is as follows:<\/strong>\n<\/p>\n\n\n\n<p>\n  1) Cast iron pipe is thick, no silence treatment is required. \n<\/p>\n\n\n\n<p>\n  2) PVC tube can be effectively solved by pipe bandage, usually can get 8 to 10dB noise reduction effect; \n<\/p>\n\n\n\n<p>\n  3) If the conditions do not allow the choice of silent drains, you can improve the noise reduction effect of about 4dB.  \n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"860\" height=\"686\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-167.jpeg\" alt=\"\" class=\"wp-image-3192\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-167.jpeg 860w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-167-300x239.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-167-768x613.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-167-600x479.jpeg 600w\" sizes=\"(max-width: 860px) 100vw, 860px\" \/><\/figure>\n\n\n\n<p><strong>6. Pipe vibration:<\/strong>\n<\/p>\n\n\n\n<p>   (1) For pipes crossing the wall, it is recommended to seal the gap between the pipe and the wall with casings and vibration cushions, and then seal with sealant, as shown below <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"567\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168.jpeg\" alt=\"\" class=\"wp-image-3193\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168-300x158.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168-1024x538.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168-768x403.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-168-600x315.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p>\n  (2) For the line groove through the wall, it is recommended to use rock wool to seal the gap with the wall, and then seal with cement mortar, the line groove needs to be lifted with an elastic hanger to avoid vibration transmission, the big picture is as follows:\n<\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1080\" height=\"939\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169.jpeg\" alt=\"\" class=\"wp-image-3194\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169.jpeg 1080w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169-300x261.jpeg 300w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169-1024x890.jpeg 1024w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169-768x668.jpeg 768w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-169-600x522.jpeg 600w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/figure>\n\n\n\n<p><strong>Your knowledge card<\/strong> <\/p>\n\n\n\n<figure class=\"wp-block-image is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"555\" height=\"2560\" src=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-scaled.jpeg\" alt=\"\" class=\"wp-image-3195\" srcset=\"https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-scaled.jpeg 555w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-65x300.jpeg 65w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-222x1024.jpeg 222w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-333x1536.jpeg 333w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-444x2048.jpeg 444w, https:\/\/epcpmo.com\/wp-content\/uploads\/2021\/11\/word-image-170-600x2766.jpeg 600w\" sizes=\"(max-width: 555px) 100vw, 555px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Hotel decorated with soundproofing 1. Most decorative s [&hellip;]<\/p>","protected":false},"author":1,"featured_media":3170,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[200,58,64,63,196,269,270,256,276],"tags":[],"class_list":["post-3175","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-management","category-hotel-project","category-process-technology","category-project-management","category-quality-control","category-269","category-270","category-256","category-276"],"_links":{"self":[{"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/posts\/3175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/comments?post=3175"}],"version-history":[{"count":1,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/posts\/3175\/revisions"}],"predecessor-version":[{"id":11195,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/posts\/3175\/revisions\/11195"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/media\/3170"}],"wp:attachment":[{"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/media?parent=3175"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/categories?post=3175"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/epcpmo.com\/en\/wp-json\/wp\/v2\/tags?post=3175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}